Place of Origin: | China |
---|---|
Brand Name: | NANBEI |
Certification: | CE/ISO/SGS/TUV |
Model Number: | GC-MS 3200 |
Minimum Order Quantity: | 1/set |
Packaging Details: | Wooden cases and cartons |
Delivery Time: | 7-10days |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability: | 500 set/per day |
Name: | Gas Chromatograph – Mass Spectrometer (Quadrupole) | LPower: | 220 V, 50 Hz |
---|---|---|---|
Temperature: | 15℃-35℃ | Humidity: | 25%-80% RH |
Column Oven Temperature: | Room Temperature + 10℃-400℃ | Temperature Stability: | ≤±0.03℃ |
Maximum Heating Rate: | 40℃/min | Maximum Run Time: | 999.99 Min |
High Light: |
80% RH gas chromatograph mass spectrometer,35C gas chromatograph mass spectrometer,80% RH gas chromatography mass spectrometry machine |
Gas Chromatograph – Mass Spectrometer (Quadrupole) with new ion optics system
Brief introduction of NBXD-8010:
Applications
The excellent performance of the GC-MS 3200 makes it suitable for applications in various fields including food safety, environmental safety, chemicals, among others.
1 Detection of Melamine in Milk
The detection limit is stable at 0.01 mg/kg. Linearity remains excellent between 0.05 - 50 mg/L. Recovery of added standard is between 85% - 108%. Relative standard deviation is less than 5%. Correlation coefficient is above 0.999. Results comply with GB / T 22388-2008 standard.
2 Analysis of Volatile Organic Compounds (VOC) in Drinking Water or Surface Water
Using external standard method, range of linearity is 0.5 - 100 μg/L. Correlation coefficient of each component is between 0.993 ~ 0.9992. The lowest detection limit is 0.001 mg/L for vinyl chloride. The instrument shows excellent performance in VOC analysis of drinking water in compliance with EPA method 502.2 and GB5749-2006.
3 Detection of Plasticizer in Liquors
16 types of phthalates in liquor are analyzed simultaneously. Range of linearity is 0.08 - 1.6 ug/mL. Recovery of added standard is between 70% - 119%. The lowest detection limit achieved is 1.06 ug/kg for DEP. Shows excellent contamination resistance. After 1 month of continuous use, background signal remains within spec.
4 Trace PAHs Detection
Linear correlation coefficient is more than 0.999 in the concentration range of 0.05 - 0.5 ug /mL.
Relative standard deviation is less than 6%. The lowest detection quality for benzopyrazole is 0.05 ng.
5 Detection of Organochlorine Pesticide
In ion monitoring mode, the analysis of organochlorine pesticide provides reliable data. Range of linearity is 0.012 - 0.2 ug/mL. Relative standard deviation is less than 10%. Lowest detection concentration reaches 0.012 ug/L.
6 Rapid Semi-quantitative Analysis of Hydrocarbons
7 Qualitative Analysis of Unknown Samples Using Direct Injection Probe
Working Conditions | |
l Power | 220 V, 50 Hz |
l Temperature | 15℃-35℃ |
l Humidity | 25%-80% RH |
Specifications | |
Gas Chromatograph | |
l Column oven temperature | Room temperature + 10℃-400℃ |
l Temperature stability | ≤±0.03℃ |
Maximum heating rate | 40℃/min |
Maximum run time | 999.99 min |
10-segment programmable temperature control | |
l Split/splitless inlet (3rd generation EPC) | |
Maximum temperature: 400℃ | |
Electronic controlled pressure, flow rate and split ratio | |
Pressure range: 0-999 kPa | |
Flow range: 0-200 mL/min | |
Autosampler (optional) | |
Mass Spectrometer | |
l Main Specifications | |
Mass range | 1.5 - 1024.0 amu |
Mass stability | Better than 0.1 amu/48 h |
Resolution | Unit mass |
Sensitivity |
DB-5MS 30m*0.25mm*0.25um fused silica capillary column or similar column. EI source, full scan: (range 100-300 amu). 1 pg OFN S/N≥100:1 |
Maximum scan rate | 10,000 amu/s |
Dynamic range | 105 |
l Ion source |
Electron impact ionization source (EI), standard. Chemical ionization source (CI), optional. |
Dual filaments | Programmable switch |
Maximum filament current | 3 A |
Emission current | 10 – 350μA adjustable |
Ionization energy | 5 – 150eV adjustable |
Ion source temperature | 150 – 320℃ adjustable, individually controlled |
l Mass analyzer |
Quadrupole. Full scan, selected ion monitoring (SIM) and acquisition. At most 128 groups in SIM mode. At most 128 ions in each group. |
l Detector | electron multiplier + high-energy dynode back focusing assembly |
l GC-MS interface | |
Individually controlled through transmission cable, 150 – 320℃ adjustable | |
l Vacuum system | |
Turbo molecular pump (250 L/s), mechanical pump (180 L/min) | |
Wide range compound cold cathode gauge | |
l Data processing system | |
Hardware | Computer (optional) |
Printer | Laser printer (optional) |
Software | MS3200RT Real-time data acquisition application and MS3200P data processing application |
Optional Accessories
|
|
DIP 100 liquid/solid direct injection probe assembly | |
Thermal desorption device | |
Dynamic headspace sampler | |
Purge-and-trap sample concentrator |