Please leave your correct email and detailed requirements.
OK
products

Gas Chromatograph – Mass Spectrometer (Quadrupole) With New Ion Optics System

Basic Information
Place of Origin: China
Brand Name: NANBEI
Certification: CE/ISO/SGS/TUV
Model Number: GC-MS 3200
Minimum Order Quantity: 1/set
Packaging Details: Wooden cases and cartons
Delivery Time: 7-10days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 500 set/per day
Detail Information
Name: Gas Chromatograph – Mass Spectrometer (Quadrupole) LPower: 220 V, 50 Hz
Temperature: 15℃-35℃ Humidity: 25%-80% RH
Column Oven Temperature: Room Temperature + 10℃-400℃ Temperature Stability: ≤±0.03℃
Maximum Heating Rate: 40℃/min Maximum Run Time: 999.99 Min
High Light:

80% RH gas chromatograph mass spectrometer

,

35C gas chromatograph mass spectrometer

,

80% RH gas chromatography mass spectrometry machine


Product Description

Gas Chromatograph – Mass Spectrometer (Quadrupole) with new ion optics system

 

Brief introduction of NBXD-8010:

Applications

The excellent performance of the GC-MS 3200 makes it suitable for applications in various fields including food safety, environmental safety, chemicals, among others.

Gas Chromatograph – Mass Spectrometer (Quadrupole) With New Ion Optics System 0

1 Detection of Melamine in Milk
The detection limit is stable at 0.01 mg/kg. Linearity remains excellent between 0.05 - 50 mg/L. Recovery of added standard is between 85% - 108%. Relative standard deviation is less than 5%. Correlation coefficient is above 0.999. Results comply with GB / T 22388-2008 standard.

 

2 Analysis of Volatile Organic Compounds (VOC) in Drinking Water or Surface Water
Using external standard method, range of linearity is 0.5 - 100 μg/L. Correlation coefficient of each component is between 0.993 ~ 0.9992. The lowest detection limit is 0.001 mg/L for vinyl chloride. The instrument shows excellent performance in VOC analysis of drinking water in compliance with EPA method 502.2 and GB5749-2006.

 

3 Detection of Plasticizer in Liquors
16 types of phthalates in liquor are analyzed simultaneously. Range of linearity is 0.08 - 1.6 ug/mL. Recovery of added standard is between 70% - 119%. The lowest detection limit achieved is 1.06 ug/kg for DEP. Shows excellent contamination resistance. After 1 month of continuous use, background signal remains within spec.

 

4 Trace PAHs Detection
Linear correlation coefficient is more than 0.999 in the concentration range of 0.05 - 0.5 ug /mL.
Relative standard deviation is less than 6%. The lowest detection quality for benzopyrazole is 0.05 ng.

5 Detection of Organochlorine Pesticide

In ion monitoring mode, the analysis of organochlorine pesticide provides reliable data. Range of linearity is 0.012 - 0.2 ug/mL. Relative standard deviation is less than 10%. Lowest detection concentration reaches 0.012 ug/L.

6 Rapid Semi-quantitative Analysis of Hydrocarbons

7 Qualitative Analysis of Unknown Samples Using Direct Injection Probe

Gas Chromatograph – Mass Spectrometer (Quadrupole) With New Ion Optics System 1Gas Chromatograph – Mass Spectrometer (Quadrupole) With New Ion Optics System 2

Working Conditions
l Power 220 V, 50 Hz
l Temperature 15℃-35℃
l Humidity 25%-80% RH
Specifications
Gas Chromatograph
l Column oven temperature Room temperature + 10℃-400℃
l Temperature stability ≤±0.03℃
Maximum heating rate 40℃/min
Maximum run time 999.99 min
10-segment programmable temperature control
l Split/splitless inlet (3rd generation EPC)
Maximum temperature: 400℃
Electronic controlled pressure, flow rate and split ratio
Pressure range: 0-999 kPa
Flow range: 0-200 mL/min
Autosampler (optional)
Mass Spectrometer
l Main Specifications
Mass range 1.5 - 1024.0 amu
Mass stability Better than 0.1 amu/48 h
Resolution Unit mass
Sensitivity

DB-5MS 30m*0.25mm*0.25um fused silica capillary column or similar column.

EI source, full scan: (range 100-300 amu).

1 pg OFN S/N≥100:1

Maximum scan rate 10,000 amu/s
Dynamic range 105
l Ion source

Electron impact ionization source (EI), standard.

Chemical ionization source (CI), optional.

Dual filaments Programmable switch
Maximum filament current 3 A
Emission current 10 – 350μA adjustable
Ionization energy 5 – 150eV adjustable
Ion source temperature 150 – 320℃ adjustable, individually controlled
l Mass analyzer

Quadrupole.

Full scan, selected ion monitoring (SIM) and acquisition.

At most 128 groups in SIM mode.

At most 128 ions in each group.

l Detector electron multiplier + high-energy dynode back focusing assembly
l GC-MS interface
Individually controlled through transmission cable, 150 – 320℃ adjustable
l Vacuum system
Turbo molecular pump (250 L/s), mechanical pump (180 L/min)
Wide range compound cold cathode gauge
l Data processing system
Hardware Computer (optional)
Printer Laser printer (optional)
Software MS3200RT Real-time data acquisition application and MS3200P data processing application

Optional Accessories

 

DIP 100 liquid/solid direct injection probe assembly
Thermal desorption device
Dynamic headspace sampler
Purge-and-trap sample concentrator

 

Gas Chromatograph – Mass Spectrometer (Quadrupole) With New Ion Optics System 3Gas Chromatograph – Mass Spectrometer (Quadrupole) With New Ion Optics System 4Gas Chromatograph – Mass Spectrometer (Quadrupole) With New Ion Optics System 5Gas Chromatograph – Mass Spectrometer (Quadrupole) With New Ion Optics System 6                         Gas Chromatograph – Mass Spectrometer (Quadrupole) With New Ion Optics System 7

Contact Details
Lin

Phone Number : +86 15890601238