Please leave your correct email and detailed requirements.
OK
products

190~900 Nm Atomic Absorption Spectrometer For Chemical Analysis

Basic Information
Place of Origin: China
Brand Name: NANBEI
Certification: CE/ISO/SGS/TUV
Model Number: AA-7020
Minimum Order Quantity: 1/set
Packaging Details: Wooden cases and cartons
Delivery Time: 7-10days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 500 set/per day
Detail Information
Wavelength Range:: 190~900 Nm Spectral Bandwidth: Automatic Switching Between 5 Levels: 0.1, 0.2, 0.4, 1.0, 2.0 Nm
Mono-chromator: C-T Grating Mono-chromator Wavelength Accuracy: ±0.1 Nm
Wavelength Repeatability: ≤0.05 Nm Grating: 1800 Lines/mm
High Light:

900Nm Atomic Absorption Spectrometer

,

190NM Atomic Absorption Spectrometer

,

900Nm aas spectrophotometer


Product Description

190~900 nm atomic absorption spectrometer for chemical analysis

 

Application for atomic absorption spectrometer

AA-7020 series atomic absorption spectrometer can be used in the fields of metallurgy, petrochemical, geology, medical science, environmental protection, scientific research, agriculture, disease control, food safety, material science, and quality inspection among others. The AA-7020 series can be used to analyze over 70 elements at both percent and trace levels.

190~900 Nm Atomic Absorption Spectrometer For Chemical Analysis 0

Features for atomic absorption spectrometer

Advanced Optical System

 

Integrated Design

 

Reliable Safety System

 

Features

High Degree of Automation

 

Additional Features

Auxiliary Gas

 

Automatic Flame Height Adjustment

 

Automatic Protection of the Liquid Trap

 

Technical Specifications

Optical System

Wavelength range: 190~900 nm

Spectral bandwidth: Automatic switching between 5 levels: 0.1, 0.2, 0.4, 1.0, 2.0 nm

Mono-chromator: C-T Grating Mono-chromator

Wavelength accuracy: ±0.1 nm

Wavelength repeatability: ≤0.05 nm

Grating: 1800 lines/mm

Blaze wavelength: 250 nm

Baseline stability: ≤±0.003A/30 min (Static)

≤±0.002A/30 min (Dynamic)

Resolution: better than 0.1nm

190~900 Nm Atomic Absorption Spectrometer For Chemical Analysis 1190~900 Nm Atomic Absorption Spectrometer For Chemical Analysis 2190~900 Nm Atomic Absorption Spectrometer For Chemical Analysis 3190~900 Nm Atomic Absorption Spectrometer For Chemical Analysis 4

Flame Method

Benchmark Concentration of Cu: ≤0.02 μg/ml

Detection Limit: ≤0.003 μg/ml

Precision RSD: ≤0.6%

Burner: Interchangeable full titanium burner of 50 mm and 100 mm

Position Adjustment: Adjustable height and angle. Flame to hydride can be switched in less than 1 minute.

Contact Details
Lin

Phone Number : +86 15890601238