Type: | NBCS-210 | Testing Port Diameter: | About 8mm |
---|---|---|---|
Measuring Range: | L*:1-100 | Measuring Time: | About 0.5 Seconds |
Measuring Light Source: | LED | Languages: | Chinese, English |
High Light: |
chemical analysis instrument,tabletop spectrophotometer |
Colorimeter Chemical Analysis Equipment Space Display Color Values
Brief introduction of Colorimeter:
Colorimeter is widely used in different industries such as plastic cement, printing, paint, weaving and dyeing. It measures the sample color data L*a*b*, L*c*h*, color difference ΔE and ΔLab according to CIE color space.
Features of Colorimeter:
1. Device sensor exports Japan and information processing chip is from USA, which guarantee the optical signal transfer accuracy and electrical signal stability. Display accuracy is 0.01, repeated test accuracy △E deviation value is below 0.08.
2. Multiple color space display color values : L*a*b,L*c*h,Yxy
Being the most commonly used testing device, our colorimeter with built-in color display indicators transformation program, which makes our device could be used for color testing in many different industries. And it do not need convert the measurement data by manual so it greatly improve the work efficiency.
3. Can Test Degree of Whiteness and Yellowness
Degree of Whiteness: Hunter whiteness, Gantz whitness
Degree of Yellowness: YI
4. Ergonomic Design
Instrument girth radian designs according to human palm so we could test data for a long time with it. Superior leather design increases the friction in case of fingers sliding.
5. Free Color Management Software
6. Establish the Prototype Data L*a*b* by manually
7. The device could store 100 standard sample groups and every sample group could store 100 sample data.
8. Test different points on sample and get the average value. It is widely used for color control whose color is not uniform.
9. Advantages
NBCS-210 includes a camera for measurement spot view. Previous color measurement instrument can only align with the test spot approximately, and can easily incur errors
Type | NBCS-210 |
Illumination system | 8/d(8°/diffused illumination) |
SCI | |
Testing Port Diameter | About 8mm |
Measuring conditions | CIE 10° standard observer; CIE D65 light source |
Measuring range | L*:1-100 |
Repeatability | Standard deviation within△E*ab*,below 0.08(testing condition: measure the white calibration board 80 times for average) |
Storage | 100 sets of standard samples; up to 100 under each standard sample |
Measuring time | About 0.5 seconds |
Measuring light source | LED |
languages | Chinese, English |
Power | Four AA1.5V Alkaline battery or nickel-metal hydride batterys; Exclusive DC5V adapter |
Port | USB2.0 printer |
Weight | 550g |
Size | 77×86×210mm |
Other Function | Build-in Micro Camera |