Contour Length: | ≤1430mm | Work Area Length: | ≥1300mm |
---|---|---|---|
Working Table Height: | 770±10mm | Clean Grade: | Grade 100(209E U.S. Federal) |
Noise: | ≤62dB(A) | Power Supply: | AC,220V/50Hz |
High Light: |
1430mm laminar flow clean bench,60 dB clean room bench |
Clean bench
clean bench Vertiacl type laminar flow for lab using
1.Product type: double single-sided clean bench
2.Airflow mode: vertical laminar flow
3. Contour length: ≤1430mm
4. Work area length: ≥1300mm
5. Working table height: 770±10mm
6. Cleanliness of work area: Class 100
7.Average number of colonies on the operating table: ≤0.5CFU(皿●0.5h)
8.Work area wind speed: 0.2-0.5m/s, three gears to choose
9.Illuminance inside the work area:≥300LX
10.Noise:≤60 dB
11.A moisture-proof, flame-retardant glass fiber filter must be used.(HEAP)
12.There is an initial pre-filter which can be replaced without tools.
13.The front window is made of tempered glass with a thickness ≥6mm.
14.The working table shall be made of 304 stainless steel with convex design on the outer edge to prevent
the spill of liquid.
15.Built-in lighting
16.At least 2 power sockets, with splash-proof function, waterproof and dustproof level is not lower than IP44.
17.The three-step interlocking function of UV lamp, lighting lamp and front window shields the risk of misoperation.
18.With the linkage function, the fluorescent lamp is automatically turned on after the door is opened, which is convenient for the experiment preparation. The fan is automatically turned off after the door is closed to prevent the fan from idling and overheating.
19.Delayed start of UV sterilization, away from UV rays: when the UV lamp is switched, the sound and light will remind the operator to leave immediately. UV lamp lights up after a delay of at least 10 seconds to protect the operator from UV exposure.
20.The time for Uv lamp to automatically light up can be preset, convenient for automatic disinfection before and after work.
21.The delayed start time of ultraviolet lamp, the length of sterilization time, the scheduled start time, the fan gear, etc. can be set according to the usage habits, and the microcomputer automatically remembers these habits.
22.The electronic control components are all arranged in the front panel, which is as high as the human sight, and can be opened with simple conventional tools, and and there is no need to move devices during maintenance
23.The base is equipped with 4 universal casters and fixed feet for easy movement and positioning.
24.Warranty: The whole machine is guaranteed for 3 years.
ParameterModel | NB-CJ-2S |
Clean grade | Grade 100(209E U.S. Federal) |
Number of bacteria | ≤0.5per utensil.hour(Φ |
90mm utensil) | |
Noise | ≤62dB(A) |
Power supply | AC,220V/50Hz |
Average Wind Speed | 0.3-0.6m/s |
Half Peak Value of vibration | ≤4um(X.Y.Z direction) |
Dimension of working area |
1340×700×520mm |
Overall dimension(W1×D1×H1) |
1500×770×1650mm |
Specification and number of high effective filter | 1320×480×50×① |