Sample Capacity(wells): | 48 | Reaction Volume: | 5-100ul |
---|---|---|---|
Consumables: | 0.2ml 8-strip Tubes,0.2ml PCR Single Tube(Optical Flat Cap. Clear Tube) | Gradient Range: | 1℃-40℃ |
Gradient Block: | 8row | Special Temperature Protocol: | Gradient PCR, Long PCR, Touch Down PCR |
High Light: |
sodium dichloroisocyanurate dihydrate,ozone disinfection machine |
Real-time pcr system Gentier48
Advantage
1. 7 inch touch screen,easy to use software
2. Ultra UniF thermal platform
3. 2 seconds lateral optical scanning
4. Non-maintenance Optical System
5. Outstanding and powerful data analysis functions
Parameters
Model | Gentier48E | Gentier48S | Gentier48R |
Thermal block | |||
Sample capacity(wells) | 48 | ||
Reaction volume | 5-100ul | ||
Consumables | 0.2ml 8-strip tubes,0.2ml PCR single tube(Optical flat cap. Clear tube) | ||
Temperature range |
0℃-100℃ |
||
Heating/cooling system | Peltier | ||
Max heating rate | 8.0℃/sec | ||
Average heating rate | 6.0℃/sec | ||
Max cooling rate | 5.5℃/sec | ||
Average cooling rate | 4.0℃/sec | ||
Temperature accuracy | ±0.1℃ | ||
Temperature uniformity | ±0.1℃ | ||
Gradient range | 1℃-40℃ | N/A | 1℃-40℃ |
Gradient block | 8row | 8row | |
Special temperature protocol | Gradient PCR, Long PCR, Touch Down PCR | Long PCR, Touch Down PCR | Gradient PCR, Long PCR, Touch Down PCR |
Heat Lid | |||
Temperature range | Room temperature-110℃ | ||
Optical system | |||
Excitation Source | 4LEDs | 2LEDs | |
Detector | Photodiode | ||
Detection position | Excitation and scan from lateral | ||
Detection method | 4 channels scanning at the same time, no edge effect | ||
Detection time | 2 seconds for 48 wells for all channels | ||
Range of excitation/emission wavelengths(nm) |
1. 465/510(FAM,SYBR Green I,SYTO9,Eva Green,LC Green) 2. 527/563(HEX,VIC,TET,JOE) 3. 580/616(ROX,Texas Red) 4. 632/664(Cy5) |
1.465/510(FAM,SYBR Green I,SYTO9,Eva Green, LC Green) 2. 527/563(HEX,VIC,TET,JOE)
|
|
Probe Taqman Probe,Molecular beacons probe, scorpion probe | |||
Multiplexing | Up to 4 targets | Up to 2 targets | |
Fluorescence Linearity | r≥0.990 | ||
Fluorescence Dynamic Range | Adjustable | ||
Performance | |||
Sample Linearity | /r/≥0.999 | ||
Sample repeatability | Ct value CV≤0.5% | ||
Sample dynamic Range | 1-1010 copies | ||
Software Functions | |||
Data Analysis Modes | Qualitative analysis, Absolute quantification, Relative quantification, Genotyping analysis, Endpoint analysis, Melt curve analysis, High Resolution Melting | ||
Control Modes |
2. PC direct control 3.WLAN control(one PC can control max 10 unis, and device can be controlled by any PC in the WLAN) |
||
Data Storage | Upload and download through USB disk, 1000 results can be stored in machine | ||
Power failure protection | Automaticly start running experiments after power supply, no need wait PC software | ||
Customize Report | Templetes reserved, report can customized | ||
Administration Management | Administratior can set functions limits for users | ||
Fault Management | Fault report and analysis,solution instruction | ||
LIS connection | CSV,Excel,TXT format data output, open port for LIS connection | ||
Others | |||
PC operating system | Win7, Win 10 | ||
Communication Port | 1 ethernet and 2 USB | ||
Foot print(WxDxH) | 260mmX400mmX260mm | ||
Weight | 11kg | ||
Power usage | AC100 to 125V/200to 240V(50/60HZ) | ||
Power consumption | 600VA | ||
Work environment | Temperature:10℃~30℃ Humidity:20%~85% |